Digital uv vis spectrophotometer
1. Photometric measurement: sa loob ng 190-1100nm, piliin ang single-point test wavelength at test method na kailangan mo para matukoy ang absorbance o transmittance ng sample.Maaari mo ring direktang basahin ang konsentrasyon ng sample sa pamamagitan ng pagpasok ng karaniwang konsentrasyon o concentration factor.
2. Quantitative measurement: Sukatin ang sample na solusyon ng hindi kilalang konsentrasyon sa pamamagitan ng curve ng mga kilalang parameter factor o awtomatikong itatag ang standard na curve ng solusyon;na may first-order, first-order zero-crossing, second-order, at third-order na curve fitting, at single wavelength correction, double Wavelength isoabsorption correction, three-point method na opsyonal;ang karaniwang kurba ay maaaring maimbak at maalala;
3. Qualitative measurement: Magtakda ng wavelength range, scan interval, at pagkatapos ay sukatin ang absorbance, transmittance, reflectance at enerhiya ng solid o liquid sample sa mga pagitan.Maaari rin itong mag-zoom, makinis, mag-filter, makakita, mag-save, mag-print, atbp. ng sinusukat na spectrum;
4. Pagsusukat ng oras: Ang pagsukat ng oras ay tinatawag ding kinetic measurement.Ang sample ay ini-scan sa mga pagitan ng hanay ng oras ng absorbance o transmittance sa nakatakdang wavelength point.Ang absorbance ay maaari ding ma-convert sa konsentrasyon o pagkalkula ng rate ng reaksyon sa pamamagitan ng pag-input ng isang kadahilanan ng konsentrasyon.
Pagkalkula ng enzyme kinetic reaction rate.Iba't ibang paraan ng pagpoproseso ng mapa tulad ng pag-scale, pagpapakinis, pag-filter, pagtuklas ng tugatog at lambak, at derivation ay magagamit para sa iyong pinili;
5. Pagsusukat ng DNA/protina: pangunahing sukatin ang absorbance sa 260nm/280nm/230nm/320nm, at makuha ang konsentrasyon at ratio ng DNA at protina ayon sa formula ng pagkalkula.
6. Multi-wavelength measurement: Maaari kang mag-set up ng hanggang 30 wavelength point para sukatin ang absorbance o transmittance ng sample solution.
7. Subsidiary functions: deuterium lamp, tungsten lamp accumulative time, deuterium lamp, tungsten lamp independent turn off and on, ultraviolet at visible light switching wavelength point selection, operating language selection (Chinese, English), wavelength automatic calibration.
Model | NU-T5 |
Optical system | Nakahanay sa sarili;1200 linya/mm na-import na holographic grating |
Saklaw ng wavelength | 190~1100nm |
Spectral bandwidth | 4nm |
Katumpakan ng wavelength | ±0.5nm |
Pag-uulit ng wavelength | ±0.2nm |
Katumpakan ng pagpapadala | ±0.5%T |
Repeatability ng transmittance | ±0.1%T |
Liwanag na ilaw | ≤0.05%T |
Noise | 0% ingay ng linya: 0.1%;100 linyang ingay: 0.15% |
Dlamat | ±0.0015Abs |
Baseline flatness | ±0.0015Abs |
Saklaw ng ningning | 0~200℅T, -0.301~3A, 0~9999C(0-9999F) |
Test mode | Absorbance, transmittance, enerhiya |
Light source | Tungsten lamp at deuterium lamp |
Montor | 4.3 pulgada 56K capacitive touch screen |
Output ng data | USB, U Disk |
Saklaw ng kapangyarihan | AC90~250V/ 50~60Hz |
Sukat L×W×H) mm | 460×310×180 |
Wwalo | 12kg |
Tandaan: Ang PC application software ay opsyonal para magkaroon ng mas maraming pagsusuri at pagproseso ng data |
■Host | 1 set |
■kurdon ng kuryente | 1 |
■Listahan ng Pag-iimpake | 1 serving |
■Sertipiko | 1 serving |
■1cm4 slot manual cuvette holder | 1 piraso |
■1cm karaniwang glass cuvette | 1 kahon (apat) |
■1cm karaniwang quartz cuvette | 1 kahon (dalawa) |
■Takip ng alikabok | 1 piraso |
■Manwal ng pagtuturo ng host | 1 kopya |
□U Disk (naka-install na may advanced na computer application software) | 1 piraso |
□linya ng komunikasyon ng USB data | 1 |
□Dongle | 1 piraso |
□Manwal ng Gumagamit ng Software | 1 kopya |